What this product does
The Emergency Two headed white light developed by ORASKA INDUSTRIES is a kind of practical and reliable emergency light source. When public electric supply stops suddenly, the emergency light turns on automatically. When public electricity supply returns to normal, it turns off automatically and recharge the batteries up to a threshold level. Moreover , with innovative energy efficient technology, the WT-P3V6Y15C can save up to 72% of power consumption for Pulsed controlled LED drive which makes an eco-friendly solution for your factories, shops, auditoriums, office buildings, hotels, banks, hospitals, post offices, scientific and educational agency, underground, family, high building and fire brigade. The Emergency Charger Light by ORASKA INDUSTRIES combines the extremely high reliability of integrated circuit enhanced technology with the most advanced protective enclosure in the industry. The system is initiated by switching the main power switch at the left side of the box. There are some indicator lights for representing the different status of the system. One is for indication of charge status. There is a main line indicator for indicating the grid line existence. In on mode, when the system is connected to the main grid line, control system will initiate the battery charging and checking the battery status whether battery is fully charged or not. If the battery is fully charged, the charging line will be disconnected. In this state, continuous checking of the battery voltage level will be going on to sense when battery is needed to be charged. When the system is on charging mode, the same checking of the voltage level is made for taking the decision when the battery is on full charged status. Up to entering that status battery charging will be on process. When the system is in the load shedding or in emergency condition (power line disconnection), the control system turns on the emergency light.
Battery Charging Specifications
- A Well Designed "Intelligent Charging System"
- Combination of trickle charging and float charging method
- Protection against overcharging and full discharging
- Emergency Conversion Time ≤ 100ms
- Full charge time 16~18 hours
- Input 180V~240V,50/60 Hz,60mA charge/time, AC main Line
- Input Power 600mW
- Full charge LED indicator, Charging/ Resting indication LED
Battery Specifications
- 6 V, 4.5 Ah Sealed Lead Acid Battery
- Aprox. 500 times charging cycle
Light Specifications
- High power 12 LED connection
- 12 Watt output power with high penetrating ability equivalent to 30 watt Halogen Lamp
- 800~850 Lumen output luminous flux
- Approx, 50~60 feet distance coverage with 450 viewing angle
- Warm yellow, Light Yellow, Warm White fog light color available
Fire panel interfacing Specifications
- 6 V to 24 V fire input signal available
- 6 V fire output signal available
- Full isolation between fire control panel and lamp
- Both wired and wireless signal transmission
- High power fire signal receiver and transmitter available
Fire signal transmitter Specifications
- 12 Watt , 4 MHz short wave transmitter
- Signal transmission range aprox. 100 -150 meter in open space
- Security coded transmission with strong firewall
- 6V inclusive and exclusive power supply
- Inclusive and exclusive transmitter module available
Fire signal receiver Specifications
- Super heterodyne powerful receiver
- 100 -150 meter receiving range
- Inclusive and exclusive receiver module available
Physical Dimensions
- 10.5 x 6 x 3.1 inch soft metal casing
- Mass / unit: 650 gm
- Fire Proof Metal Body
Features
- Heavy Duty Battery 6V- 4.5 AH
- 2 Hours Intelligent Backup
- Battery Test Switch
- Charging Status Indication
- Protection against battery overcharging and full discharging for longer battery life
- Auto Light up during power failure
- Built in AC Charger
- External panel mount safety fuse
- 12 watt LED Light
- 4 inch dome reflector for wider light distribution
- Fire Alarm Indecator
Specification
- Input voltage: 180V-240V,60mA,50/60Hz
- Lamps: 2×6Watt LED Light
- Luminous Flux: 800-850 Lumen net directional output
- Luminous Intensity: 25 LUX Light at 10 feet distance @ Full Charge
- Battery: 6V-4.5AH Heavy Duty
- Recharging Time: 16-18 Hours
- Fire Input Signal: 6V-24V
- Isolation: Full Isolation between fire panel and Light module
- Response Time: Less than 800 ms
- Capacity of Fully Charge Battery: 5 Hours
- Operating Relative Humidity : Less than 85%
- Operating Temperature: -10C to 70C
Operation and Maintenance
- The unit should be charged for 24 hours before initial operation.
- It usually be installed in stairs, gate, and door channels and so on. Distance with the floor about 1.8 meter. There are two pieces hooks in the back of the light, can be hung the wall easily.
- Add the DC insurance and 220V public electricity, it will work after recharged 18 hours.
- The unit should always be connected with AC power source and the master switch be turned to the ON position for it to light up automatically after power failure. The light will be turned off automatically after 2 hours and the system will hibernate to prolong battery life.
- Blue indicator light show public electricity, Yellow Indicator Light show battery already filled, Red indicator light stop means recharging, Red indicator light means Fire Alarm.
Caution
- Do not touch the device with bare hand if your body is grounded.
- Make sure to unplug the unit before changing the fuse.
- Make sure to turn off all the switches if the device is not in use for a long time.
- To prolong battery life, charge the battery for 24 hours when the lamp is not in use. It is also advisable to discharge the battery for every 3 months.
- Do not power up the device if the circuit is not connected with the battery unit.